BIO-DL was established in 2013, located in Songjiang District, Shanghai, China, with an office area of more than 3,000 square meters; it is a comprehensive company integrating R&D, production and trade, and has a worldwide sales network and service centers. BIO-DL is dedicated to offering high quality technology products and services, as well as creating pleasant experiences for the users.
Product Introduction of K3 PRO Automatic Microplate Reader for Quantitative Elisa Assay
K3 Pro is a Microplate Reader with reliable and flexible functions which can measure the absorbance value of the samples in microplate. It can be configured with up to 8 optical filters at the same time, and the detection range of wave length is 340-850nmFurthermore, it is also configured with a heating incubator and an oscillator to meet the needs of variable experiments. A 10-inchcolortouch screen is chosen to be one of major operate methods and the software is visible pictorial, therefore the K3 Pro is very easy to use.
Purpose of K3 PRO Automatic Microplate Reader for Quantitative Elisa Assay
1. K3 Pro is a high-precision microplate reader, which can be used to measure the absorbance value of the applicable 96 hole microplate and Flat noodles, and can also choose to measure the absorbance value of the 384 hole microplate conforming to ANSI/SBS standards.
2. Professionals can use K3 Pro in research or daily experiments.
3. K3 Pro is used for end-user analysis systems, so end-users are responsible for verifying whether the entire system can produce reliable and secure results.
If testing performance is crucial for analysis, the measured results must be ensured through internal quality control or another measurement.
During the analysis process, it is recommended to adopt Good Laboratory Practice (GLP).
Features of K3 PRO Automatic Microplate Reader for Quantitative Elisa Assay
Detection range of wave length:330-900nm.
Dual detection mode(continuous and stepping), it takes only 8s for one test of96 orifice plate.
A variety of program detection modes available, including single wave, double wave, dual-time method, dynamic and multi-wave mode.
10-inchlarge touch screen, simple interface, easy to use.
An adjustable heating incubator(RT +4'c-55°C) and an adjustable oscillator(with 3 optional speeds) are configured as standard.
Wild readingrange:0-6 Abs. Flexible for more applications.
Connect to PC by wire or WiFi, or operate by stand-alone software.
Installation environment requirements
When setting up K3 Pro, the operating area should avoid excessive dust, vibration, strong magnetic fields, direct sunlight, ventilation, excessive humidity, or large temperature fluctuations. Ensure that the work area is flat, dry, clean, and vibration free, and leave additional space for components such as power cords and top covers;
The ambient air is clean and free of corrosive steam and smoke; The ambient temperature is between+10 ° C and+40 ° C; Low humidity to ensure no condensation occurs (relative humidity between 10% and 80%, no condensation).
Maintenance and upkeep of K3 PRO Automatic Microplate Reader for Quantitative Elisa Assay
Keep the instrument away from dust.
Avoid interfering with any optical system components, including light source lamps and filter wheel cavity covers.
Clean and inspect the filter and filter wheel groove.
Immediately wipe off any spilled physiological saline solution, solvent, acid or alkali solution from the outside to prevent damage, and wipe with deionized distilled water.
If the surface is contaminated with biochemical hazardous substances, disinfect it with mild disinfectant.
Regularly clean the instrument.
If necessary, clean the carrier rack.
If the filament is broken, please replace the bulb.
Ensure that the instrument is properly turned off.
Please perform decontamination treatment when moving instruments or conducting maintenance and transportation.
Regular maintenance of instruments.
Technical parameter of K3 PRO Automatic Microplate Reader for Quantitative Elisa Assay
Light source | Quartz halogen lamp |
Wave length range | 330-900nm |
Microplate mode | 96-384 orifice plate |
Optical filters | 8 hole sites optical filter wheel with 405nm&450nm&620nmfilters for standard configuration |
Half-band width | 3-9nm |
Reading range | 0-6Abs |
Linear range | 0-4Abs @405nm.(0-3Abs ±2% in rapid measure mode;0-4Abs +2%in common measure mode) |
Accuracy | 士1%(0-3Abs)@405nm;+2%(3-4Abs) @405nm |
Precision | Cv≤ 0.2%(0-3Abs);CV≤ 1.0%(3-4Abs) @405nm |
Measuring speed | For 96 orifice plate: 8s in rapid measure mode and 12s in common measure mode,for 384 orifice plate: 16s in rapid measure mode and 24s in common measure mode |
Heating incubator | RT + 4℃-55℃(configured for standard) |
Oscillator | 3 speed levels optional linear oscillator (configured for standard) |
Display & operate | 10-inch HD color touch screen |
Language | Chinese & English |
Data export | USB |
Printer | USB/WiFi |
Internal storage program capacity | 1000 programs |
PC software | configured for standard |
Packaging & shipping of K3 PRO Automatic Microplate Reader for Quantitative Elisa Assay
Our Factory
Our Team
Our Client
FAQ
Q: How about quality of the goods?
A: All the running products comply with CE standards.
Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.
Q: Is OEM service available.