Shanghai BIO-DL Science Instrument Co., Ltd (BIO-DL) is a professional Channel Sterilizer manufacturer of experimental instruments, mainly producing commonly used experimental instruments such as pipettes, microplate reader, ultra micro spectrophotometer, microplate washing machines, sealing machines, and tearing machines.
Product Introduction
Shanghai BIO-DL Science Instrument Co., Ltd (BIO-DL) is a professional Channel Sterilizer manufacturer of experimental instruments, mainly producing commonly used experimental instruments such as pipettes, microplate reader, ultra micro spectrophotometer, microplate washing machines, sealing machines, and tearing machines.
Bio-1 is the latest generation pipette of BIO-DL, entire pipette is autoclavable, anti-chemical corrosion and anti-ultraviolet materials.Optilock's dual-function volume locking prevents accidental volume changes, optiload tips install structure makes install and eject more easily, Including 0.1ul~10ml single channel and 0.5ul~300ul multiple channel.
Sterilize the entire pipette to eliminate all potential hazards
It can withstand high-temperature and high-pressure sterilization treatment as a whole. All components, including the handle, sleeve, and piston, are made of special materials that are resistant to high temperatures and chemical corrosion. Under the conditions of wet heat sterilization at 121°C for 15 - 20 minutes, the fully autoclavable pipette can easily cope with the process. Without the need for cumbersome disassembly, it can completely eliminate all potential microorganisms, eradicating the risk of cross-contamination during experiments at the source. Whether it is the strict control of cell purity in cell culture, the precise manipulation of nucleic acid samples in molecular cloning experiments, or the accurate handling of bacterial strains in microbiological research, the fully autoclavable pipette can safeguard the safety of your experiments and make your data more reliable.
High-precision pipetting ensures absolute accuracy without the slightest deviation.
Precise pipetting is the key to the success of experiments. BIO-1 offers superior pipetting accuracy and repeatability, with an extremely wide range of volume settings, covering from as low as 0.1 μL for trace amounts to as high as 10 mL for routine volumes. Whether you are handling precious trace samples or performing routine volume transfers, it can ensure the stability and accuracy of your experimental data with its outstanding precision.
Humanized design ensures worry-free operation
The handle and finger hook of the BIO-1 pipette are both ergonomically designed to provide you with a comfortable grip. It is easy to use and offers a pleasant tactile experience. The BIO-1 can reduce your workload and prevent hand fatigue, allowing you to effortlessly complete hours of pipetting operations. The pipette fits your hand perfectly, enabling you to hold the handle with minimal effort.
Reliable results
You can press the volume lock button with one hand, adjust the volume with the other hand, and then release the lock. Or, you can simply slide the volume lock upward with one hand, adjust the volume, and slide it downward to set and lock the volume. Everything is under your control.
The volume display shows four clear and easy-to-read digits, allowing you to check the set volume and reducing eye strain. With the BIO-1, you can clearly read the last digit, and you can directly read the volume even when the pipette is tilted, without having to awkwardly adjust the position of your head.
With its outstanding performance, the BIO-1 fully autoclavable pipette plays a crucial role in multiple scientific research fields. In cell biology experiments, procedures such as cell passage, transfection, and stem cell culture demand an extremely high standard of aseptic environment. The BIO-1 can prevent contamination by exogenous microorganisms, ensuring the purity of cell cultures. In molecular cloning experiments, during processes like DNA/RNA extraction, PCR system preparation, and plasmid construction, it can prevent contamination of enzymes or nucleic acids, ensuring the smooth progress of experiments. In microbiological research, for tasks such as bacterial strain inoculation, preparation of sterile solutions, and pathogen detection, the fully autoclavable pipette also shines brightly, effectively eliminating residual pathogens and safeguarding biosafety.
Choosing the BIO-1 fully autoclavable pipette means choosing higher experimental standards, more reliable experimental results, and a more efficient scientific research experience.
Product Description
NO. | Channels | Range | Measuring Volume | Inaccuracy | Imprecision |
72741021 | 1-ch | 0.1-3μl |
3.0μl 1.5μl 0.3μl |
±1.30% ±2.40% ±10.00% |
0.80% 1.60% 6.00% |
72741031 | 1-ch | 0.5 - 10μl |
10μl 5μl 1μl |
±1.00% ±1.50% ±2.50% |
0.60% 1.00% 1.50% |
72741041 | 1-ch | 2 - 20μl |
20μl 10μl 2μl |
±0.90% ±1.20% ±3.00% |
0.40% 1.00% 2.00% |
72741061 | 1-ch | 10 - 100μl |
100μl 50μl 10 μl |
±0.80% ±1.00% ±2.00% |
0.15% 0.40% 1.00% |
72741071 | 1-ch | 20 - 200μl |
200μl 100μl 20 μl |
±0.60% ±0.80% ±2.30% |
0.15% 0.30% 0.90% |
72741081 | 1-ch | 100 - 1000μl |
1000μl 500μl 100μl |
±0.70% ±0.70% ±2.00% |
0.20% 0.20% 0.50% |
72741091 | 1-ch | 500 - 5000μl |
5000μl 2500μl 500μl |
±0.50% ±0.60% ±2.00% |
0.20% 0.30% 0.60% |
72741111 | 1-ch | 1-10ml |
10000ul 5000ul 1000ul |
±0.60% ±1.20% ±3.00% |
0.20% 0.30% 0.60% |
72711031 | 8-ch | 0.5 - 10μl |
10μl 5μl 1μl |
±1.50% ±2.50% ±4.00% |
1.50% 2.50% 4.00% |
72711121 | 8-ch | 5 - 100μl |
10μl 5μl 10μl |
±0.70% ±1.00% ±3.00% |
0.25% 0.70% 1.50% |
72711131 | 8-ch | 30 - 300μl |
300μl 150μl 30μl |
±0.60% ±1.00% ±2.00% |
0.25% 0.50% 1.00% |
72721031 | 12-ch | 0.5 - 10μl |
10μl 5μl 1μl |
±1.50% ±2.50% ±4.00% |
1.50% 2.50% 4.00% |
72721121 | 12-ch | 5 - 100μl |
100μl 500μl 10μl |
±0.70% ±1.00% ±3.00% |
0.25% 0.70% 1.50% |
72721131 | 12-ch | 30 - 300μl |
300μl 150μl 30μl |
±0.60% ±1.00% ±2.00% |
0.25% 0.50% 1.00% |
Packaging & shipping
Our Factory
Our Team
Our Client
FAQ
Q: How about quality of the goods?
A: All the running products comply with CE standards.
Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.
Q: Is OEM service available.
A: All of the running products are available for OEM customization, including logo and package.
Q:What are the core differences between fully autoclavable pipettes and ordinary pipettes?
A:The core advantage of fully autoclavable pipettes lies in their ability to be sterilized as a whole. Ordinary pipettes usually only allow for the sterilization of some components, whereas for fully autoclavable pipettes, all components, from the handle and sleeve to the piston, can withstand high-temperature and high-pressure wet heat sterilization at 121°C for 15 - 20 minutes. Without the need for cumbersome disassembly, they can completely eliminate potential microorganisms, eradicating the risk of cross-contamination in experiments at the source. This makes them more suitable for experimental scenarios with extremely strict requirements for aseptic operation.
Q:Will the performance of fully autoclavable pipettes be affected by multiple sterilizations?
A:No. Components such as the handle, sleeve, and piston of fully autoclavable pipettes are all made of special materials that are resistant to high temperatures and chemical corrosion. These pipettes can withstand multiple high-temperature and high-pressure sterilization processes. Moreover, during the design and manufacturing process, they have undergone stringent durability tests. Even after multiple sterilizations, they can maintain excellent mechanical properties, pipetting accuracy, and sealing performance, without affecting normal use.